DMC-40x0 Command Reference BV • 55
BV
FUNCTION: Burn Variables & Arrays
DESCRIPTION::
The BV command saves the controller variables and arrays in non-volatile EEPROM memory.
This command typically takes up to 2 seconds to execute and must not be interrupted. The
controller returns a : when the Burn is complete.
ARGUMENTS: None
USAGE: DEFAULTS:
While Moving Yes Default Value ---
In a Program Yes
Not in a Program Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_BV returns the number of controller axes.
RELATED COMMANDS:
BN Burn Parameters
BP Burn Program
Note 1: This command will store the ECAM table values in non-volatile EEPROM memory.
Note 2: This command may cause the Galil software to issue the following warning "A time-out occurred
while waiting for a response from the controller". This warning is normal and is designed to warn the user
when the controller does not respond to a command within the timeout period. This occurs because this
command takes more time than the default timeout of 5 sec. The timeout can be changed in the Galil
software but this warning does not affect the operation of the controller or software.