DMC-40x0 Command Reference DT • 85
CD 400,200 ;'Countour Data pre-loaded in buffer
CD 200,100 ;'Countour Data pre-loaded in buffer
CD 300,50 ;'Countour Data pre-loaded in buffer
AI -1 ;'Wait for Analog input 1 to go low
DT 8 ;'Set positive DT to start contour mode
CD 0,0,0,0=0
#Wait;JP#Wait,_CM<>511
;'End of Contour Buffer/Sequence
;'Wait until path is done