Page 28
SW+ LATCH New Feature this output is now fully programmable.
This terminal is high (+12V) when the system is set and low (0V) when the system is
unset. Typical use for this terminal would be the latch signal for PIRs and Shockgards
etc. A maximum sink of 50mA *
1 T
This terminal may be programmed for other uses.
DET RESET New Feature this output is now fully programmable.
This +VE supply terminal is provided for the types of detectors that require the removal
of power to reset them. In the default mode the 12V supply from this terminal will pulse
off for three seconds during the exit time. The terminal is also programmable for other
uses (see Programmable Options Description for more details). A maximum current
draw of 50mA*
1
is available. This terminal is programmable for other uses.
STROBE + | -
This pair of terminals provide power for the strobe light during and after an alarm. The
negative terminal is switched. A maximum current of 1Amp*
1
can be switched with
these terminals. This terminal is programmable for other uses. The terminal is
redundant if the NovActive range of bell boxes is used.
BELL + | -
This pair of terminals provide power for the bell during an alarm. The negative terminal
is switched. A maximum current draw of 1Amp*
1
is available from these terminals.
The positive terminal also provides the positive hold off for the SAB.
In SCB mode (see Programmable Options Description), the terminals stand at + & -.
The negative terminal will change state to positive for the duration of the alarm.
It should be noted that the operation of the bell is influenced by the
programmable options Bell Delay, Bell Ring Time and Number of Arms (see
Programmable Options Descriptions for more details).
BELL HOLD -
This terminal is the negative tamper feed and also provides the negative Hold Off for
the SAB.
The terminal has a factory fitted link fitted to the SAB TMP terminal in order to keep the
bell tamper clear. This link should be removed as the bell wiring is connected.
SAB TMP
This terminal is the tamper return from the Bell Box. If unused the factory fitted link to
Bell Hold- should be left in place.
*
1
No attempt should be made to exceed the stated current and the 1 Amp
maximum current draw from the control panel must be taken into consideration..
GardTec 872Wiring Connections