Chapter 3: Programming
84 Concord 4 Installation Manual
System master
Shortcut: 0320
Default: 1234
The system master code provides access to all system operations and user
programming. In the partition where the indicating power device is located,
only the system master code may be enabled to disarm that partition.
To change the system master code:
1. With the display showing USER CODES, press # then A or B until the
display shows SYSTEM MASTER CODE.
2. Press # and the display shows SYSTEM MASTER nnnn (current code).
3. Enter a new four-digit code. The display flashes the entered code. Press #
and display shows the new code.
Options menu
The Options menu lets you set up the system for downloading and silent arming. You
can also adjust alphanumeric touchpad display brightness from this menu.
Downloading
Shortcut: 041
Default: On
When this setting is on, the panel can communicate with Enterprise
Downloader software for programming the system from offsite.
For this feature to work, the panel must be connected to a phone line and
be programmed with remote access on, with a Downloader phone number,
and with a Downloader code.
Touchpad brightness
Shortcut: 043
Default: 2
This setting lets the user lighten or darken the background on touchpad
displays. Each touchpad can be set to compensate for lighting conditions in
the touchpad location. Enter a setting from 0 (darkest background) to 3
(brightest background).
Volume
Shortcut: 044
Default: 4
This setting determines the volume level of status sounds from speakers
connected to the phone interface/voice module or voice only module (VOM).
This menu setting appears only if a phone interface/voice module or a VOM
is connected to the panel. Enter a setting from 0 (off) to 7 (loudest).
Voice chime
Shortcut: 045
Default: On
This setting determines whether speakers connected to the phone
interface/voice module or voice-only module announce perimeter
sensor/zone numbers that are tripped when the chime feature is on. This
menu appears only if a phone interface/voice module or a VOM is
connected to the panel.
Chime on close
Shortcut: 046
Default: Off
When this setting is on, the panel sounds a single chime when a perimeter
door or window is closed.

Table of Contents

Other manuals for GE Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 and is the answer not in the manual?

GE Concord 4 Specifications

General IconGeneral
Zones96
Partitions6
User Codes230
Power Supply16.5 VAC, 40 VA
Wireless CompatibilityCompatible with GE wireless sensors
KeypadsUp to 8
Outputs2 onboard, expandable
Event Log512 events
Backup Battery12VDC, 7AH
CommunicationPhone line, optional cellular or IP