– 21 –
Note: A microwave leakage test must be performed
any time a door is removed, replaced, disassembled,
or adjusted for any reason. The maximum allowable
leakage is 4 MW/CM².
Door Assembly Remova
l
To remove the door assembly, remove the hinge
clip by gently prying it straight out with a small, at
blade screwdriver.
Door Assembly
The door comes as an entire assembly, although,
the door handle can be obtained separately.
Lift door to disengage upper and lower door hinge
the pins from the hinge arms.
Hinge Clip
(Continued next page)