3. V BUSBAR ONLY REQUIRED IF CHECK SYNCHRONISM FUNCTION ENABLED.
IN FAULT LOCATOR.
4. MUTUAL CURRENT INPUT ONLY REQUIRED IF ENABLED
5. C.T. CONNECTIONS ARE SHOWN 1A CONNECTED AND ARE TYPICAL ONLY.
TO ENSURE CORRECT OPERATION OF THE PROTECTIVE RELAY.
6. THIS RELAY SHOULD BE ASSIGNED TO ANY TRIP
DRIVEN FROM A CORE BALANCE CT WHEN SENSITIVE
2. USED FOR SEF PROTECTION. SENSITIVE SHOULD BE
SETTINGS ARE USED.
N
+
V BUSBAR
(SEE NOTE 3.)
C
D24
D22
D23
B
A
D20
D21
D19
+
C18
C17
C16
C15
+
-
C14
C13
+
-
C12
C11
+
-
+
+
C10
C9
-
C8
C7
-
+
C6
C5
-
C4
C3
-
NOTE 5.
NOTE 2.
DIRECTION OF FORWARD CURRENT FLOW
a
b
c
n
E4
SENSITIVE
N
4.
NOTE
M
D15
1A
D13
D12
5A
1A
C
B
5AD7
D9
D10 5A
1A
D6
D4
1A
5A
C2
C1
-
E18
E17
+
+
E16
E15
-
E14
E13
-
+
E8
E10
E11
E12
-
+
E9
-
+
E6
E7
-
+
E5
-
+
MiCOM P545 (PART)
A
D3
D1
1A
5A
E2
E3
-
+
E1
-
CONNECTION
COMMON
OPTO 16
OPTO 15
OPTO 14
OPTO 13
OPTO 12
OPTO 11
OPTO 10
OPTO 2
CONNECTION
OPTO 9
COMMON
OPTO 8
OPTO 7
OPTO 4
OPTO 6
OPTO 5
OPTO 3
OPTO 1
POWER SUPPLY VERSION 24-48V (NOMINAL) D.C. ONLY
*
AC OR DC
x
-
+
M1
M2
*
K15
K18
K16
K17
RELAY 15
K14
K13
K11
K12
K10
RELAY 14
RELAY 13
MiCOM P545 (PART)
M16
SCN
M18
M17
RELAY 11
RELAY 10
RELAY 9
K7
K9
K8
K6
K5
RELAY 12
K2
K3
K4
K1
L12
L11
RELAY 7
RELAY 6
L8
L7
RELAY 5
RELAY 4
RELAY 3 ANY TRIP
NOTE 6.
M11
RELAY 1
L2
L6
L5
L4
L3
RELAY 2
L1
M14
M12
M13
WATCHDOG
CONTACT
CONTACT
WATCHDOG
L9
L10
L13
L14
L17
L16
L15
L18
RELAY 8
RELAY 16
OPTO 17
OPTO 18
OPTO 19
OPTO 20
OPTO 21
OPTO 22
OPTO 23
OPTO 24
-
G1
+
-
G3
G4
+
-
G5
G6
-
G7
G8
-
G9
G10
+
+
-
G11
G12
-
G13
G14
+
-
G15
G16
G17
+
+
+
G2
COMMON
CONNECTION
G18
RELAY 20
RELAY 21
RELAY 22
RELAY 23
RELAY 24
J16
J15
J17
J18
J10
J12
J13
J14
J11
J5
J7
J8
J9
J6
J1
J3
J2
J4
RELAY 18
RELAY 17
RELAY 19
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13
H14
H15
H16
H17
H18
RELAY 25
RELAY 26
RELAY 27
RELAY 28
RELAY 29
RELAY 30
RELAY 31
RELAY 32
COMMUNICATION
CURR DIFF
FIBRE OPTIC
TX1
TX2
RX1
RX2
RX1
CONNECT TO P594
N
NOTE 7
+
EIA485/
KBUS
PORT
-
IF THIS OPTION IS SELECTED IN THE RELAY MENU.
7. OPTO INPUTS 1 & 2 MUST BE USED FOR SETTING GROUP
8. FOR COMMS OPTIONS SEE DRAWING 10Px4001.
SEE DRAWING
10Px4001
B.KIRBY
Drg
No:
Issue: Revision:
Date:
Date:
Name:
Chkd:
DO NOT SCALE
CAD DATA 1:1 DIMENSIONS: mm
Title:
Substation Automation Solutions
ALSTOM GRID UK LTD
(STAFFORD)
Sht:
Next
Sht:
28/06/2013 N.JOHNSON
FIELD VOLTAGE OUTPUT REMOVED. CID HONG-98JC6A.
10P54501
1
2
EXTERNAL CONNECTION DIAGRAM: CURRENT DIFFERENTIAL RELAY (80TE)
WITH DISTANCE, 1 OR 3 POLE TRIPPING, AUTO-RECLOSE & CHECK SYNCH
H