H-4 T60 Transformer Protection System GE Multilin
H.1 CHANGE NOTES APPENDIX H
H
3-10 3-10 Update Updated Figure 3-12 Typical Wiring Diagram
3-23 3-23 Update Deleted references to COM 1 RS485 port in section 3.2.9 CPU Communication Ports. Revised
text and Figure 3-24 CPU Module Communications Wiring to include only modules T, U, V in
section 3.2.9a.
5-1 5-1 Update Updated the front panel main menu to include the CyberSentry security menu
5-15 5-15 Update Update Communications main menu to remove the SNTP Protocol submenu
5-16 5-16 Delete Deleted references to COM 1 RS485 port in section 5.2.4b Serial Ports
5-17 5-17 Add Added section 5.2.4c Ethernet Network Topology
5-18 5-18 Update Updated Networks section 5.2.4d to include all three Ethernet ports
5-18 5-18 Update Added 0 as valid number to section 5.2.4e Modbus Protocol section
5-40 5- Delete Deleted Local Time Offset, Daylight Savings Time, DST (start/stop for month/day/hour) from Real
Time Clock menu
5- 5-40 Add Added submenus Precision Time Protocol, SNTP Protocol, and Local Time and Synchronizing
Source settings to Real Time Clock menu
5- 5-42 Add Added new Precision Time Protocol (1588) menu and setting descriptions
5- 5- Update Changed Communication to Real Time Clock in SNTP protocol settings path. Moved SNTP
Protocol menu and settings descriptions to Real Time Clock subsection
5-37 5- Delete Deleted section k) SNTP Protocol and the settings descriptions
5- 5-45 Add Added new section for Local Time menu settings and settings description
5- 5-55 Add Added new PTP Fail menu item to the User-Programmable Self Tests menu
5- 5- Add Added PTP Failure and CLOCK UNSYNCHRONIZED to Flexlogic Operands table
5-84 5-84 Update Updated Transformer setup main menu to include Winding 6 menu item
5-86 5-86 Update Updated General setup main menu to change winding range from 5 to 6
5-108 5-108 Update Updated PMU main menu to add aggregator and control block menu items
5- 5-108 Add Added UR Synchrophasor Implementation of IEC61850-90-5 to the PMU software option
description
5-108 5-108 Update Updated Figure: Complete Synchrophasor Implementation
5- 5-109 Add Added Figure: N60 Support For Four Logical Device PMU
5-109 5-109 Update Updated Table: Implementation By Model Number
5- 5-110 Add Added Figure: Logical Nodes Supported In Each Logical Device
5- 5-111 Add Added Figure: Data Set Created From User Selected Internal Items
5- 5-111 Add Added Figure: Example Of Aggregator Data Sets
5- 5-112 Add Added Figure: CFG-2 Based Configuration Solution
5- 5-113 Add Added examples for a syncrophasor dataset and the creation of different datasets
5- 5-111 Add Added example for a CFG-2 based configuration
5-114 5-114 Update Updated PMU 1 basic configuration menu to add 37.118 and 90-5 configuration settings
submenus
5- 5-115 Add Added PMU 1 configuration menus for 37.118 and 90-5 with settings descriptions
5- 5-115 Update Changed PMU 1 Function setting description
5- 5-125 Add Added PMU AGGR 1 configuration menu and setting descriptions
5- 5-125 Add Added new aggregators section with PMU 1 aggregators menu and setting descriptions
5-125 5-125 Update Updated PMU 1 aggregators menu to include 37.118 and 90-5 aggregator configuration
submenus
5- 5-126 Add Added 90-5 AGGR 1 configuration menu and setting descriptions
5- 5-127 Add Added Table 5- # Of ASDUs
5- 5-127 Add Added new control block section with IEC 90-5 MSVCB configuration menu and setting
descriptions
5- 5-150 Update Added row for DeltaTime to Table 5-: FlexElement Base Units
5-276 5-276 Delete Deleted section 5.8.5c Remote Devices: ID of Device for Receiving GSSE/GOOSE Messages,
meaning the Settings > Input/Outputs > Remote Devices settings
Table H–6: MAJOR UPDATES FOR T60 MANUAL REVISION Y1 (Sheet 2 of 3)
PAGE
(X2)
PAGE
(Y1)
CHANGE DESCRIPTION