0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
24.27 4572Motorovldactivity ENUM Warning 0 4 ERW FVS
Setting of the behaviour of the drive in case of a motor overload alarm Motorovld[14]. This alarm indicates
that the motor overload threshold has been reached.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
24.28 4574Bresovldactivity ENUM Disable 0 4 ERW FVS
Setting of the behaviour of the drive in case of a braking resistor overload alarm Bresovld. This alarm indi-
cates that the braking resistor overload threshold has been reached.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
24.29 4582HTsensrestart ENUM Disable 0 1 ERW FVS
Enabling of automatic restart after the drive heatsink overtemperature alarm HeatsinkSOTUT[10].
0 Disable
1 Enable
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
24.30 4584HTsensrestarttime ms UINT16 20000 120 60000 ERW FVS
Setting of the time within which the HeatsinkSOTUT[10]alarm must be reset in order to perform automatic
restart.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
24.31 4600InAiractivity ENUM Stop 0 4 ERW FVS
Setting of the behaviour of the drive in case of an intake air overtemperature alarmIntakeairOT[11].This
alarm indicates that the temperature of the intake cooling air is too high.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
24.32 4602InAirrestart ENUM Disable 0 1 ERW FVS
Enabling of automatic restart after the intake air overtemperature alarm IntakeairOT[11].
0 Disable
1 Enable