174 ADV200 Functions description and parameters list
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
3262Bresoverloadtrip BIT 16 0 0 1 ER
This signal is active when the drive is in the braking resistor overload alarm condition.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
3374Vfcatchout INT32 16 0 0 0 ER
The voltage applied during capture on-the-y of the motor in Vf mode is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
3442Powerlossrampdown BIT 16 0 0 1 ER
This parameter indicates the status of the Powerloss function deceleration ramp
0 Powerloss function deceleration ramp not ended
1 Powerloss function deceleration ramp ended
The signal is enabled at the end of the Powerloss function deceleration ramp.
The signal is disabled at different times depending on the Powerlossmode setting.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
3446Powerlossnextratio INT32 32 0 0 0 ER
This parameter gives the ratio between the motor speed and the speed reference.
For machines with several drives, line synchronisation can be achieved by connecting the Powerlossmode
output of the master to the Speedratiosrc input of the slave drives. The master => slave connection can be
achieved via analog signals or eldbus.
The value 2^30 corresponds to a ratio of 1.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
3448Powerlossnextactive BIT 16 0 0 1 ER
This parameter indicates the status of the Powerloss function
0 Powerloss not enabled
1 Powerloss enabled
The function is enabled when there is a power failure.
The function is disabled at different times depending on the Powerlossmode setting.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
3480Vdcctrlrampfreeze BIT 16 0 0 1 ER
This parameter displays when the deceleration ramp block is requested during the Vdccontrolfunction.
0 VdcCtrl function not enabled
1 VdcCtrl function enabled
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
3512Drvthrovertempmon UINT32 0 0 1 ER
Signals that the threshold set in PAR 3504 Drvtempthrhas been exceeded.
0 Threshold not exceeded
1 Threshold exceeded
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
3514Motthrovertempmon UINT32 0 0 1 ER
Signals that the threshold set in PAR 3506 Mottempthrhas been exceeded.

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals