AVy -HGB
Ch.7 110
V/Hz functions
V out
f
ENERGY SAVE
Voltage Boost
AVy_Ovw
Overview
NAVIGATION
AVy_Funct
Go to functions
Slip Compensation
Torque
Speed
V
f
V/f shape
V/f speed search
T
Enable
Base voltage
460V
Base frequency
60 Hz
V/f shape
V =k*f1.0
Vlt boost type
Manual
Manual boost
1%
Slip comp type
Manual
Manual slip comp
0rpm
Slip comp filt
0.03 s
Flux var time
10 s
Enable save eng
Disable
Lock save eng
Off
Actual boost Actual slip comp
V/f flux level
Auto capture
100 %
Motor losses
0%
Regulation mode
V/f Control
Spd srch time
10 s
Flux srch time
1s
Spd auto capture
1500 rpm
Delay auto cap
1000 ms
Delay retrying
1000 ms