Ch.7121
——— Block diagram ———
DC Braking function
AVy_Ovw
Overview
NAVIGATION
AVy_Funct
Go to functions
DC Braking mode
selection
T
Speed
100 %
IDC
Zero
spd
threshold
DC Braking mode 0
Speed
100 %
IDC
Zero
spd
threshold
DC Braking mode 1
F
Ramp stop
Quick stop
DC Braking
current
DC braking mode
DC braking curr
50 %
DC braking delay
500 ms
DC braking curr
50 %
Brk time @ stop
1000 ms
QStp opt code
File name:AVy_DCBR.vsd