Group 12: Monitoring Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/f
V/f
+PG
SLV SV
PM
SV
PM
SLV
SLV2
12-12
Output Voltage of Current
Fault
Display the output voltage of current fault - V O O O O O O O
12-13
Output Frequency of Current
Fault
Display the output frequency of current
fault
- Hz O O O O O O O
12-14 DC Voltage of Current Fault Display the DC voltage of current fault - V O O O O O O O
12-15
Frequency Command of
Current Fault
Display the frequency command of
current fault
- Hz O O O O O O O
12-16 Frequency Command
If LED enters this parameter, it only allows
monitoring frequency command.
- Hz O O O O O O O
12-17 Output Frequency Display the current output frequency - Hz O O O O O O O
12-18 Output Current Display the current output current - A O O O O O O O
12-19 Output Voltage Display the current output voltage - V O O O O O O O
12-20 DC Voltage (Vdc) Display the current DC voltage - V O O O O O O O
12-21 Output Power (kw) Display the current output power - kW O O O O O O O
12-22
Motor’s Rotation Speed
(rpm)
Display motor’s current rotation speed.
In VF/SLV mode the speed is estimated by
output power
- rpm O O O O O O O
In PG/SV mode, motor’s rotation speed is
calculated by feedback frequency.
Max limit is 65535
12-23 Output Power Factor (Pfo) Display the current output power factor - - O O O O O O O
12-24 Control Mode Display control mode - - O O O O O O O
0: VF
1: PG
2: SLV
3: SV
4: PSV
5: PMSLV
6: SLV2
12-25 AI1 Input
Display the current Al1 input
(-10V corresponds to -100%, 10V corre-
sponds to 100%,)
- % O O O O O O O
12-26 AI2 Input
Display the current Al2 input
(0V or 4mA corresponds to 0%, 10V or
20mA corresponds to 100%)
- % O O O O O O O
12-27 Motor Torque
Display the current torque command
(100% corresponds to motor torque )
- % X X O O O O X
12-28 Motor Torque Current (Iq) Display the current q-axis current - % X X O O O O X
12-29
Motor Excitation Current
(Id)
Display the current d-axis current - % X X O O O O X
12-30 ASR Deviation
Display deviation of speed controller
(speed command - speed feedback)
(100% corresponds to the maximum
frequency set by 01-02 )
- % X O X O O X X
12-31 Reserved
12-32 ASR Output
Display output value of speed controller
(100% corresponds to the maximum
frequency set by 01-02)
- % X O X O O X X
12-33 PG Feedback
Display feedback’s speed value of speed
controller
(100% corresponds to the maximum
frequency set by 01-02)
- % X O X O O X X
12-34 Reserved
12-35 Zero-servo Pulse
When display SV position mode, the
position error pulse number of the zero
speed servo
(the pulse number of a circle is four times
of set values of 20-27)
- Pulse X X X O O X X
VDI100 • Start-up and Installation Manual 51