129 50940193/DP0415
Removing Foreign Material
Remove dirt and other foreign matter from the following areas daily before operating the
machine:
Around the lift cylinders.
At the front of the machine.
On the attachment hitch, especially around the tilt cylinder.
Around hydraulic oil reservoir breather.
In the engine compartment.
In the operator’s compartment.
Important: Build-up of foreign materials in these areas can interfere with machine
operation, cause component damage or become a fire hazard.
Tilting the ROPS/FOPS
Never operate the machine with the ROPS/FOPS in
the raised position or removed. Be sure to reinstall
the anchor bolts, washers and locknuts before using the machine.
Torque to 43 Nm (32 lb-ft).
Always close the cab door before tilting the ROPS/FOPS. Stay clear
from underneath the ROPS/FOPS as it is tilted.
Be sure the lock is securely engaged when the ROPS/FOPS is raised.
Properly support the ROPS/FOPS when unlatching the lock mechanism
and lowering the ROPS/FOPS.
Raising the ROPS/FOPS
1. Perform the “Mandatory Safety Shutdown
Procedure” on page 14.
2. Remove hardware (A, Figure 87) at the
front of the ROPS/FOPS.
WARNING
Figure 87 – ROPS/FOPS
Anchor Hardware
A