162 50940193/DP0415
Indicator Lamp Troubleshooting
Table 24: Indicator Lamp Troubleshooting
Indicator Icon Indicator Activated Possible Cause Corrective Action
Engine oil pressure
Engine oil pressure too
low.
Stop engine immediately;
check oil level and top off
oil if necessary; check oil
pump.
Engine oil level too low.
Top off oil. See “Fluid
Capacities/Lubricants” on
page 183 for proper oil
grade.
Oil pump malfunction. Contact dealer.
Hydraulic oil temperature
Oil temperature is too hot.
Check cooling system for
debris in radiator.
Check hydraulic oil level.
See “Checking Hydraulic
Oil Level” on page 143.
Drive system continuously
overloaded.
Improve operation
procedure.
Lift/tilt or auxiliary system
continuously overloaded.
Improve operation
procedure.
Drive motor(s) or
hydrostatic pump(s)
internal damage/leakage.
Contact dealer.
Hydraulic oil filter
restricted.
Replace filter.
Radiator/cooler restricted. Clean radiator/cooler.
Hydraulic oil filter
Hydraulic oil filter service
required.
Replace hydraulic oil and
filter. See “Hydraulic
System” on page 142
NOTE: During cold start in
cold temperatures, this
indicator may be activated
until hydraulic oil warms to
operating temperature.
Coolant temperature
Coolant level too low.
Top off coolant. See
“Coolant Compound
Mixtures” on page 189 for
proper coolant mixture.
Air filter plugged.
Replace air filter(s). See
“Changing Air Filter
Elements” on page 139.
Coolant leak.
Repair cooling system and
top-off coolant.