The adjusted value of the total air volume can be left as it is, as
long as the same diameter powder hose is used. If the hose
diameter changes, the total air volume must be reset!
Setting the powder output
1.
Adjust the powder output volume (e.g. according to the desired
coating thickness)
– Factory default setting of 60% is recommended for initial
operation. The total air volume is thereby kept constant
automatically by the control unit.
To achieve maximum efficiency, we recommend using the lowest
possible powder volume where possible!
2. Check fluidization of the powder in the powder container
3. Point the gun into the booth, switch the gun on and visually check
the powder output