2.2 Environmental Information
The strapping machine shall be installed in the following conditions:
⚫ Supply voltage: +-10% nominal supply voltage
⚫ Source frequency: +-10% nominal frequency
⚫ Ambient temperature: 5°C - 40°C (41℉-104℉).
⚫ Relative humidity: not exceed 35~85%RH
⚫ Please provide a suitable illumination around the machine for safety operation.
Conditions For Use
Make sure there is room for easy application and maintenance
The machine must be installed in a closed, well-ventilated area where there are no
explosions or fire hazards Position the machine in a place free of humidity, flammable
materials, gas or explosives. Make sure that it is level.
Please do not spray water or wet wipe machine body.
Noise - characteristic values
The noise emission values determined according to EN ISO 3746 for the sound power level
or EN ISO 11202 for the sound pressure level at the workplace on the basis of the working
conditions are as below:
A measurement uncertainty allowance of K = 4 dB(A) applies to the stated emission values.
Sound power level L
WA
= 88.7 dB(A)
Emission sound pressure level at the workplace L
PA
= 75.3 dB(A)
To minimize the emission sound pressure level, machine is equipped with a timer standby
mode that can be adjusted by technician.
Demolition and Waste Disposal
The machine does not contain dangerous components or substances which require special
disposal procedure. For that which concerns material elimination, comply with the
Standards in the country where the machine has been disassembled.
Caution: do not leave waste polypropylene strap on the floor to minimize slip hazards.