26
4.3 Setting Page
(D) Shows current setting of machine, operator could change the setting through the
Potentiometer.
COOLING TIME _ _ S:
This is strap welding cooling timer adjust. If you have big tension with hard package,
longer cooling time could help you with better seal on strap.
Press Potentiometer number _ _ will start twinkle rotate Potentiometer to
change value (from 0.0 to 1.0) press Potentiometer to confirm
HEATER TEMP _ _ _ %
This is heater plate temperature setting. This setting is depend on working
environment and strap material, sometime cooler surrounding temperature or thicker
strap material would need higher temperature setting on the heater plate.
Press Potentiometer number _ _ will start twinkle rotate Potentiometer to
change value (from 0 to 100) press Potentiometer to confirm