5.4 ELECTRICAL EMERGENCY OPERATION
IN THE PRESENCE OF ELECTRICITY
IMPORTANT!
Only perform the operation on the maintenance push-button panel in the electrical cabinet.
IMPORTANT!
Warn trapped people of the impending car movement before starting the emergency operation.
To perform the electrical emergency operation in the presence of electricity, proceed as follows:
STEP
ACTION PICTURE
1
Turn the switch “SMMQ” from [NORMAL] to [INSPECTION].
2
Press the buttons “SGOQ” and “SMSQ” to move [UP] or “SGOQ” and
“SMDQ” to move [DOWN] until the floor is reached and the “HZP” LED
lights up.
3
Check the direction and speed of the car on the display (if provided).
Alternatively, it is possible to display the direction with the “FS” (up) or
“FD” (down) LEDs and the speed with the position LEDs from PS1” to
“PS6” on the basic board “STK1R”.
4
After releasing the car, turn the switch SMMQ” from [INSPECTION]
back to [NORMAL].