EXIT SEQUENCE
STEP
ACTION
1
Bring the car to the next floor above the pit by traditional call.
2
Press the emergency stop (red button).
3
Turn the selector switch on the maintenance push-button panel to “automatic operation”.
4
Detach the ladder from its storage housing and place it ready to climb out of the pit.
5
Open the landing door to the pit by pulling the lock release cable on the door.
6
Climb out of the pit up to the entrance landing.
7
Put the ladder back into its storage housing.
8
Release the emergency stop (red button).
9
Close the landing door.
10
Turn the key on the “RESET” switch outside the landing to reset the electrical panel functions (buzzer).
11
The lift is back in service (floor call buttons are not lit).
IMPORTANT!
When exiting the pit and/or the car roof, the maintenance technician is advised to ensure that no
equipment or tools have been left behind that can impair smooth operation of the lift or even