Nevertheless, there is only one limit stop contact in the headroom that stops the car moving up
when it reaches it.
This contact is positioned to anticipate the impact of the counterweight on the buffer.
EXIT SEQUENCE (ROOF)
STEP
ACTION
1
Press the emergency stop (red button).
2
Turn the selector switch on the maintenance push-button panel to “automatic operation”.
3
Open the landing door at the floor where you have decided to exit, unlocking the lock manually.
4
Climb down from the roof and stand on the landing.
5
Release the emergency stop (red button).
6
Close the landing door.
7
Turn the key on the “RESET” switch outside the landing to reset the electrical panel functions (buzzer).
8
The lift is back in service (floor call buttons are not lit).
IMPORTANT!
When exiting the pit and/or the car roof, the maintenance technician is advised to ensure that no
equipment or tools have been left behind that can impair smooth operation of the lift or even
cause accidents.