User Manual V1.5-2021-01-21 03 MANUAL OPERATION
Note:
1. Please make sure the password and encryption method/algorithm are the same as those of the
router.
2. If everything went well, the WiFi indicator on the inverter will change from a double blink to 4 blink
and then to a steady status, which means that the WiFi has successfully connected to the server.
WiFi Reset & Reload
WiFi reset means restarting the WiFi module. The WiFi settings will automatically be reprocessed
and saved. WiFi Reload means setting the WiFi module to the default factory settings.
WiFi reset
Short press the touch button
for about one second, Wi-Fi
LED on inverter will blink once
a second;
WiFi reload
Long press the touch button
(3~5 seconds)
Wi-Fi LED on inverter will
quartic blink.
Note: Wi-Fi Reset & Reload function is only used when:
1. Wi-Fi lost connection to internet or cannot connect to PV Master APP successfully.
2. Cannot nd “Solar-WiFi signal” or have other Wi-Fi conguration problem.
3. Please do not use this button if Wi-Fi monitoring works well.
PV Master is an external monitoring and conguration application for hybrid inverters and is
used on smart phones or tablets for both Andriod and iOS systems. The main functions are
listed as below:
1. Congure the system to customize functions by the user.
2. Monitor and check the performance of the hybrid system.
3. Access and change the regional settings.
4. Check the inverter rmware version.
5. Set export power limit.
6. Check fault alarms.
Search PV Master in Google Play or Apple App Store, or scan the QR
code to download the app.
Operation steps are the same for Android system and iOS system
although the two interfaces are slightly dierent.
For more detailed opertaion instructions, please refer to PV Master
user manual in www.goodwe.com.
PV Master App
3.2 PV Master
Note:
For Australian customers please select from Australia Region A/B/C to comply with AS/NZS 4777.2:2020.
Contact local grid operator to see which Region to select. After setting the safety region, some
parameters in the inverter system will take eect according to the corresponding safety regulations, such
as PU curve, QU curve, trip protection, etc. If you need to change the conguration parameters, please
refer to the PV Master user manual.
Wi-Fi
Reset/Reload
SYSTEM
GRID
BACK-UP
ENERGY
COM
Wi-Fi
BATTERY
FAULT
2019
Wi-Fi
Reset/Reload
Touch Button

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe SBP Series and is the answer not in the manual?

Goodwe SBP Series Specifications

General IconGeneral
BrandGoodwe
ModelSBP Series
CategoryInverter
LanguageEnglish

Related product manuals