User Manual V1.5-2021-01-21 04 OTHER
30
Maximum output overcurrent
protection (A)
40 50
Output Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Output THDi (@Nominal Output) <3% <3%
Max. Output Fault Current(peak and
duration) (A)
70A,3us 70A,3us
AC Output Data (Back-up)
Back-up Rated apparent power (VA) 3680 5000
Max. Output Apparent Power (VA)
*5
3680 5000
Peak Output Apparent Power (VA)
*5
4416, 10sec 5500, 10sec
Rated Output Current (A) 16 21.7
Max. Output Fault Current(peak and
duration) (A)
70A,3us 70A,3us
Inrush Current(peak and duration) (A) 100A,20us 100A,20us
Maximum output overcurrent
protection (A)
40 50
Automatic Switch Time (ms) <10 <10
Rated Output Voltage (V) 230 (±2%) 230 (±2%)
Rated Output Frequency (Hz) 50/60 (±0.2%) 50/60 (±0.2%)
Max. Output Current (A) 16 22.8
Output THDv (@Linear Load) <3% <3%
Eciency
Max. Eciency 95.5% 95.5%
European Eciency 94% 94%
Max. Battery to Load Eciency 95.5% 95.5%
Protection
Anti-islanding Protection AFDPF + AQDPF
*6
AFDPF + AQDPF
*6
Output Over Current Protection Integrated Integrated
Output Short Protection Integrated Integrated
Output Over Voltage Protection Integrated Integrated
General Data
Operating Temperature Range (℃) -25~60 -25~60
Relative Humidity 0~95% 0~95%