Operation
14.TosettheMediaTrak(ZD),slowlyadjustthe
abrasivemeteringvalve(T)whiletheabrasive
isblastingfromthenozzletoreachthedesired
setpoint.
8800000
8800000
NOTE: NOTE:
NOTE:
Youmayhavetowait1–2minutesforthe
abrasivematerialtoreachthenozzle.
NOTE: NOTE:
NOTE:
Useapieceoftestmaterialsimilarto
whatyouwillbeblasting.Alwaysstartasgently
aspossibleandthenincreasetheblastforceas
necessarytocleanwithoutdoinganydamageto
thesubstrate.
EQs2 EQs2
EQs2
Elite Elite
Elite
Blast Blast
Blast
Pressure Pressure
Pressure
Setting Setting
Setting
1.Turnbothblastpressureregulatorsalltheway
in(CW).
2.Blastwithnozzleoneandnozzletwoandrecord
theblastpressurefromtheblastpressuregauge.
3.Blastwithnozzleoneandsettheblastpressure
atorbelowtherecordedblastpressurefromstep
2.
4.Blastwithnozzletwoandsettheblastpressure
atorbelowtherecordedblastpressurefromstep
2.
5.Continuefromstep13on