Troubleshooting
3A8099A 29
No fluid output when triggered. Spray tip is plugged. Clean spray tip. See Cleaning Procedure,
page 22.
Fluid hose is plugged. Follow Pressure Relief Procedure, page 15.
Very slowly loosen the hose end coupling to
relieve pressure gradually. Loosen the nut or
the coupling completely. Clear the obstruction
in the hose.
Then loosen completely to clear the
obstruction.
Fluid filter is plugged. Follow Pressure Relief Procedure, page 15.
Unscrew the fluid inlet fitting. Remove and
inspect the inline fluid filter. Clean or replace
the inline fluid filter as necessary.
Problem Cause Solution

Table of Contents