Startup
g. Hold gun fluid manifold over two grounded
waste containers. Open fluid valves A and B
until clean, air-free fluid comes from valves.
Close valves.
The Fusion AP gun manifold is shown.
14. Press to activate the system.
15. Preheat the system:
This equipment is used with heated fluid which
can cause equipment surfaces to become very
hot. To avoid severe burns:
Do not touch hot fluid or equipment.
Do not turn on hose heat without fluid in
hoses.
Allow equipment to cool completely before
touching it.
Wear gloves if uid temperature exceeds
110°F (43°C).
Thermal expansion can cause
overpressurization, resulting in equipment
rupture and serious injury, including uid
injection. Do not pressurize system when
preheating hose.
a. Press to turn on hose heat zone.
b. Wait for the engine to reach operating
temperature, indicated when the black arrow
is under the green area of the temperature
bar. Theradiatorfanwillturnonwhen
operating temperature is reached.
c. Wait for the hose to reach set point
temperature.
d. Press to turn on A and B heat zones.
60 332636C

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor 2 Series and is the answer not in the manual?

Graco Reactor 2 Series Specifications

General IconGeneral
BrandGraco
ModelReactor 2 Series
CategoryWater Pump
LanguageEnglish

Related product manuals