Important Isocyanate Information
Foam Resins with 245 fa Blowing
Agents
Some foam blowing agents will froth at temperatures
above 90°F (33°C) when not under pressure,
especially if agitated. To reduce frothing, minimize
preheating in a circulation system.
Changing Materials
NOTICE
Changing the material types used in your
equipment requires special attention to avoid
equipment damage and downtime.
When changing materials, flush the equipment
multiple times to ensure it is thoroughly clean.
Always clean the fluid inlet strainers after
flushing.
Check with your material manufacturer for
chemical compatibility.
When changing between epoxies and urethanes
or polyureas, disassemble and clean all fluid
components and change hoses. Epoxies often
have amines on the B (hardener) side. Polyureas
often have amines on the B (resin) side.
332636C 9