7 ELECTRICAL ADJUSTMENTS
7.4 Clearing the Non-Volatile RAM
When you replace the main board, you must clear the Non-Volatile RAM (NOV-RAM).
If you clear the Non-Volatile RAM, you will lose the setup parameters for each adjustment.
Input the adjustment values to the main board after you clear the Non-Volatile RAM.
How to clear the Non-Volatile RAM.
(1) Set SW1 to the NOV-RAM clear mode as shown below.
Dip Switch 1 2 3 4 Model
SW1
1234
ON
OFF
OFF OFF OFF ON
CE6000-40
CE6000-40 Plus
SW1
1234
ON
OFF
ON OFF OFF ON
CE6000-60
CE6000-60 Plus
SW1
1234
ON
OFF
OFF ON OFF ON
CE6000-120/120AMO
CE6000-120 Plus
SW1
1234
ON
OFF
ON ON OFF ON CE6000-120AP
(2) Turn on the power to the plotter.
(3) The SET DEFAULT menu appears. The plotter immediately starts to clear the parameters on the
NOV-RAM, and then sets the default values.
Do not turn off the power when the above menu is displaying.
It will take about one minute to set the default settings.
(4) When the default setting was nished, the COMPLETE message appears on the LCD panel.
(5) Turn off the power to the plotter.
(6) Return the SW1 setting to normal mode as shown in the subsection 7.1.
(7) Conrm the sufx setting which is corresponding to the model (See section 7.6.).