CE6000-UM-251-9370 7-25
7 ELECTRICAL ADJUSTMENTS
7.11 Adjusting the RMS sensor and the Paper sensor position
This adjustment will set the registration mark sensor position and the paper position.
If you have replaced the registration mark sensor or the paper sensor, you must adjust the RMS sensor
and the paper sensor position.
If you replace the main board, use the following procedure to input the recorded adjustment values.
Preparation
Make a following adjustment target sheet.
170 mm
150 mm
130 mm
30 mm
Make a 100 mm X 20 mm square
hole with A4 size of copy paper at
the showing position.
The adjustment target sheet does not need to make if the recorded adjustment values are input.
How to set the registration mark sensor and the Paper sensor position
(1) Set an target sheet of paper into the plotter.
Note: The front media sensor should be covered by the front area of the target sheet to read the front
edge of the target sheet when the target sheet is loading into the plotter.
Set the A4 size of paper if the recorded adjustment values are input.
(2) Turn on the power while pressing the FAST and ENTER keys.
(3) Select the Language and the Length Unit if the Language selection menu is displayed (See section
7.5.).
(4) Press the F3 key (SHEET) when the following menu is displayed.