CE6000-UM-251-9370 6-33
6 DISASSEMBLY AND REASSEMBLY
6.2.18 Vacuum Fan for the CE6000-120
How to detach the vacuum fan
(1) Detach the right cover (See section 6.1.1.).
(2) Detach the front guide (See section 6.1.5.).
M3L35 binding head screw
Fan relay board
Fan
Fan cover
M4L8 binding head screw
(3) Remove the harness tie-wrap holding the vacuum fan cables.
(4) Disconnect the vacuum fan cable from the connector on the fan relay board. (Right side fan)
Disconnect the vacuum fan cable from the fan extension cable. (Left side fan)
(5) Remove the M4L8 binding screw holding the fan cover, and then detach the fan cover.
(6) Use a long screwdriver to remove the two M3L35 binding head screws holding the vacuum fan
from the main frame.
(7) Detach the vacuum fan from the main frame.
How to reinstall the vacuum fan
(1) Reattach in the reverse order in which it was detached.