CE6000-UM-251-9370 7-37
7 ELECTRICAL ADJUSTMENTS
7.15 Upgrading the System Firmware
To upgrade the system rmware you need to have the following les. In addition, you need to use a
computer and USB cable.
For CE6000-40/60/120
CE6000_Vxx.x.X CE6000 rmware
SEND.EXE Utility to transfer les using Windows
®
OPS662 USB Driver software for CE6000
For CE6000-40 Plus/60 Plus/120 Plus
CE6000Plus_Vxx.x.X CE6000 Plus rmware
SEND.EXE Utility to transfer les using Windows
®
OPS662 USB Driver software for CE6000 Plus (Use later than version 3.21)
For CE6000-120AP
CE6000AP_Vxx.x.X CE6000-120AP rmware
SEND.EXE Utility to transfer les using Windows
®
OPS662 USB Driver software for CE6000 (The USB Driver is same as CE6000 when in
the firmware update mode.)
Note: The rmware of CE6000-120AP can’t install to the main-board of the CE6000. And the rmware of
CE6000 can’t install to the main-board of CE6000-120AP.
The rmware of CE6000 Plus Series can't install to the main-board of the CE6000 and CE6000-
120AP.
Install the correct main-board for each model when updating the rmware..
Main Board for the CE6000-40/60/120: 792600750 Main Board, CE6000
Main Board for the CE6000-120AP: 792600730 Main Board, CE6000-120AP
Main Board for the CE6000-40 Plus/60 Plus/120 Plus: 792600760 Main Board, CE6000Plus
Preparation
Install the USB Driver software to your computer before upgrading the system rmware.
Conrm the Cutting Master 3 or the Graphtec Studio is not running on the PC.
How to upgrade the system rmware
(1) Connect the computer and the CE6000 via the USB interface.
(2) Turn on the power while pressing the RIGHT ARROW key and the LEFT ARROW key to display the
menu shown below.
PLEASE SEND PRG.
CE6000
BOOT: V1.00
FPGA: 10
(3) Send rmware to the plotter from the computer.
Execute SEND.EXE.
Select the system rmware le from the SEND.EXE menu.
Select CE6000 from the output menu. (Select the type of le to all les when select the rmware le.)
Output the system rmware le to the CE6000.