CE6000-UM-251-9370 7-15
7 ELECTRICAL ADJUSTMENTS
(12) Remove the paper and measure the X-axis, the Y-axis distances and the diagonal distance (XY).
Input the adjustment values for the X, the Y, and the diagonal distance.
The formula of the input value is as follows:
Input value for X-axis = 250 mm - measured X distance
Input value for Y-axis = 250 mm - measured Y distance
For example:
If you measured 249.0 mm for the Y-axis then input 1 mm for the adjustment value.
Adjustable range: -5.0 mm to +5.0 mm , 0.01 mm steps
Input value for diagonal distance = measured diagonal distance
Press the F2 key (X=) to input the X-axis distance adjustment value.
Press the F3 key (Y=) to input the Y-axis distance adjustment value.
Press the F4 key (XY=) to input the diagonal distance adjustment value.
Press the Up or Down arrow key to change the adjustment value.
Press the Left arrow key after the adjustment value was input.
(13) Press the ENTER key to set the adjustemt value.
(14) The following menu is displayed.

Table of Contents