CE6000-UM-251-9370 7-23
7 ELECTRICAL ADJUSTMENTS
(16) Measure the offset between the printed cross mark and plotted cross mark.
Media feed
direction
Printed target mark
Cross mark
plotted by the
plotter
Y
X
+Y -Y
+X
-X
Press the F3 (X=) or F4 (Y=) to input the measured adjustment values.
Input the measured adjustment value by using the Up arrow key or Down arrow key with the following
menu.
Press the Left arrow key after input the measured adjustment values. The following menu is
displayed.
Press the ENTER key to store the value.
(17) Verify that the plotted cross mark line is located at the center of the printed cross mark line. Move
the pen to the printed cross mark area. Press the ENTER key to repeat the scan as described in step
(14) and (15).
(18) Repeat steps (14) and (15) if the location of the plotted cross mark is incorrectly positioned.
(19) Turn off the power.