CE6000-UM-251-9370 7-34
7 ELECTRICAL ADJUSTMENTS
(18) Press the F3 key to display the menu shown below.
(19) Set the Y-offset value. Press the UP ARROW key or DOWN ARROW key to change the number
based on the pen 1 cross mark.
(20) Press the left position key when the Y direction is adjusted.
(21) Press the F2 key. Verify that the plotted pen 1 cross mark is located at the center of the plotted pen 2
lines.
(22) If the plotted cross marks are in the correct positions, press the ENTER key to store the setting and
complete the adjustment.