CE6000-UM-251-9370 12-6
12 Target electrical component for WEEE instruction
(6) Remove the two M3L6 binding head screws holding the Pen-relay board, and then detch the Pen-
relay board.
• Removing (D) Control Panel Board, CE6000, (E) LCD, BTG240128SFBWBGG, CE6000
(1) Detach the right side cover.
(2) Disconnect the control panel exible cable from the main board.
(3) Remove the three M3L5 binding head screws holding the control panel assembly, and then detach
the control panel assembly.
M3L5 binding head screw
Control panel exible cable
Control panel assembly
(4) Disconnect the LCD exible cable from the control panel key board.
LCD exible cable
(5) Remove the ve M2L5 self-tapping screws holding the control panel key board.
M2L5 self tapping screw
Control panel key board