6 DISASSEMBLY AND REASSEMBLY
(7) Fit the Y-exible cable into the Y-rail as shown below. The Y-exible cable shouldn’t touch the
left side plate. Allow a 10 mm space between the left end of the Y-exible cable and the left side
plate.
Allow a 10 mm space between the left end of
the Y-exible cable and the left side plate.
10 mm
(8) Secure the Y-exible cable onto the exible cable guide of the Y-rail using double-sided adhesive
tape.
(9) Reattach the other parts in the reverse order in which they were detached.