6 – 4 CS400/300
6. TROUBLESHOOTING PROCEDURES
Original document Data overlaps
Original document Data is missing
Original document Deviation caused
by specifications
6.8 The Input Image Data Is Incorrectly Aligned
Cause Remedy
The data is misaligned at a joint between After opening the Tools menu of the driver program
the image sensors. (see the figure on (Scanning Master 21+ driver) provided with your
page 6-5) scanner, select the Joint Adjustment function
then perform adjustment to achieve a seamless
image.
Your scanner comes shipped from the factory after being adjusted for high precision.
Due to its operating environment or other factors, however, the scanning precision
may deviate in very rare cases.
Moreover, fine adjustment to correct such deviation can be performed using the driver
software if the deviation causes are overlapped or missing data.
Overlapped data
Missing data
Deviation due to scanner specifications