FC7000-UM-251-9370 8-2
8. SERVICE MODES
8.2 Control Panel Switch Test Mode
This mode checks the control panel switch status. If there is a bad switch you may have trouble with the
control panel switch panel or the control panel relay board.
How to test the control panel switches
(1) Load an A2 or larger size sheet of paper in the plotter.
(2) Enter the adjustment menu (see Section 7.3.6).
(3) Press the MENU key to display the menu shown below.
SENSOR TEST
KEY TEST
PEN FORCE
XY GAIN
(4) Press the NEXT key until the menu shown below is displayed.
SENSOR TEST
KEY TEST
PEN FORCE
XY GAIN
(5) Press the F2 key to display the menu shown below.
00000000
00000000
(6) Press each key on the control panel; the status will change from “0” to “1”.
The status of each digit:
Key Status Bit
LEFT ARROW
(-Y) 1st row 1st digit
NEXT 1st row 2nd digit
AXIS/RM 1st row 3rd digit
1st row 4th digit
CONDITION 1st row 5th digit
RIGHT ARROW
(+Y) 1st row 6th digit
DOWN ARROW (-X)
1st row 7th digit
UP ARROW (+X)
1st row 8th digit
F1 2nd row 1st digit
F2 2nd row 2nd digit
F3 2nd row 3rd digit
F4 2nd row 4th digit
COPY 2nd row 5th digit
TEST 2nd row 6th digit
ORIGIN 2nd row 7th digit
ENTER 2nd row 8th digit
PAUSE STATUS Lamp
(lights when the PAUSE key is pressed, but only the first time)
(7) When testing is completed, turn off the power to the plotter.