EasyManua.ls Logo

GRAPHTEC FC7000-130 - Adjusting the Pen Exchange y Direction Value (2-Pen Model)

GRAPHTEC FC7000-130
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FC7000-UM-251-9370 7-27
7. ADJUSTMENT
7.3.14 Adjusting the Pen Exchange Y Direction Value (2-pen model)
This adjustment will set the pen exchange Y direction value.
This value is used for the 2nd pen pen exchange.
If you replace the main board, use the following procedure to input the recorded adjustment values.
(1) Confirm that DIP switch 6 of SW1 is OFF. (2-pen model mode)
(2) Enter the adjustment menu (see Section 7.3.6).
(3) Press the MENU key to display the menu shown below.
SENSOR TEST
KEY TEST
PEN FORCE
XY GAIN
(4) Load an A2 or larger size sheet of paper in the plotter.
(5) Mount a disposable ink pen (0.2 mm tip size) in the 2nd pen station.
(6) Set the plotting conditions to the following settings:
Force: 12, Speed: 40, Quality: 1, Tool: Pen
(7) Lower the media set lever to raise the pinch rollers, and then raise the media set lever to detect the
paper size.
The menu shown below is displayed after the media set lever is raised.
CONDITION 12
40
READY 1
PEN
(8) Press the MENU key to display the menu shown below.
SENSOR TEST
KEY TEST
PEN FORCE
XY GAIN
(9) Press the NEXT key until the menu shown below is displayed.
1/2 PEN POSITION ADJ
DISTANCE ADJUST
2 PEN EXCHANGE ADJ
RM SENSOR LEVEL ADJ
(10) Press the F3 key to display the following menu for moving the second pen holder to the second pen
station.
PENSELE ACTION>
PENSELE POS.
+ 70 (0.05mm)
(11) Press the F1 key; the 2nd pen holder moves to the 2nd pen station and takes the second pen.
Press the F2 key; the 2nd pen holder stops at the exchange position.