FC7000-UM-251-9370 7-17
7. ADJUSTMENT
(10) Adjust the 300g-pen force. If the measured value is within the specification range (300±20g) or if you
have input the recorded value, press the ENTER key to store the setting. The next specified pen force
appears.
(11) Adjust the 450 (400) g-pen force. If the measured value is within the specification range (FC7000: 450
±20g, FC7000Mk2 and FC7000 with new main board, 9 Series: 400±20g ) or if you have input the
recorded value, press the ENTER key to store the setting.
Note: When adjusting the pen force, it is important to do it quickly. Delaying the pen force adjustment
changes the temperature of the actuator and causes artificially lower readings. When this happens the
actual pen force may be higher than the specification. This is especially true for the upper pen force
adjustment.
(12) Press the NEXT key to complete this adjustment.
(13) Turn off the power to exit from the adjustment menu.
Specification of the actual pen force
Specified pen force
Actual force range
FC7000
FC7000 with new
Main boaed
FC7000MK2 9 Series
10g 8 to 12g 8 to 12g 8 to 12g 8 to 12g
40g 36 to 44g 36 to 44g 36 to 44g 36 to 44g
120g 110 to 130g 110 to 130g 110 to 130g 110 to 130g
300g 280 to 320g 280 to 320g 280 to 320g 280 to 320g
450g (400g) 430 to 470g 380 to 420g 380 to 420g 380 to 420g