80 Planning and Installation Manual
256 x 256 frame: 26 A/supply (full redundancy).
512 x 512 frame: approx. 26 A/supply (full redundancy).
Current sharing: Yes, maximum 20% differential unbalance
Ripple/noise: <200 mVp-p
DC Power Input
Input voltage range 42-54 VDC
Operating current 128 x 128 frame: approx. 9.5 A @ 48 VDC.
256 x 256 frame: approx. 16 A @ 48 VDC.
512 x 512 frame: approx. 34 A @ 48 VDC.
Inrush current 128 x 128 frame: 15 A.
256 x 256 frame: 21 A.
512 x 512 frame: approx. 25 A.
Alarm
The relay connector is a BNC type and meets SMPTE 269M-1999 (see Glossary).
Environmental
0 to +35 degrees C (+32 to +95 F)
Physical
128 x 128 frame
14 inches (8 RU) high x 19 in. wide x 17.50 in. deep (356 x 483 x 445 mm)
256 x 256 frame
26.25 inches (15 RU) high x 19 in. wide x 17.5 in. deep (667 x 483 x 445 mm)
512 x 512 frame
Main chassis: 49 inches (28 RU) high x 19 in. wide x 17.5 in. deep (1245 x 483 x 445
mm)Power supply chassis: 7 inches (4 RU) high x 19 in. wide x 21 in. deep (178 x
483 x 533 mm)
MK-33000 Mounting Kit (for port expansion)
14 inches (8 RU) high x 19 in. wide x approximately 4 in. deep (356 x 483 x 100
mm)

Table of Contents