Any use other than the intended use is considered incorrect use. The legal warranty is voided by any
interference with, or modications to, the device.
Danger due to insufcient wire cross-section!
If wires with an insufciently large cross-section are used, short circuits or res may occur.
− Only use terminals with a cross-section between 0.5mm² and 2.5mm² for wires.
WARNING!
Damage to the clock timer due to incorrect installation location!
If installed in an unsuitable location, the clock timer may be damaged.
− Only use the clock timer in dry rooms and do not install close to devices with inductive
discharge (motors, transformers, etc.).
− Only install the clock timer on DIN rails.
NOTE!
Residual risks
The device is state-of-the art and designed in accordance with current safety requirements.
However, residual risks remain that require caution when using the device. The residual risks, and the
conduct and measures they require, are listed in the following.
Electric current
Life-threatening danger from electric shock!
Improper assembly and installation of the device can lead to life-threatening electrical
voltages.
− Only allow a qualied electrician to install and connect the device.