Removal of compressor/gas liquid separator
NOTE: Before removing the compressor/gas liquid separator, make sure there is no refrigerant in the pipeline and power is cut off.
Step
Picture
Work instruction
2. Break off the pipes that
connecting to the
compressor/gas liquid
separator.
Weld the pipes that are
connected to the
compressor/gas liquid
separator.
Then remove the pipes.
NOTE: When welding the
pipes, do not let the flame
burn the other
components.
3. Loosen the compressor’s
base connectors / gas
liquid separator’s base
nuts.
Screws
Use a wrench to twist off
the compressor/gas liquid
separator’s base nuts.
4. Remove the
compressor/gas liquid
separator from the chassis.
Take away the
compressor/gas liquid
separator and replace with
a new one.
NOTE: When replacing
the compressor/gas liquid
separator, avoid touching
the nearby pipeline and
components.

Other manuals for Gree FLEXX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree FLEXX Series and is the answer not in the manual?

Gree FLEXX Series Specifications

General IconGeneral
TypeHeat Pump
SeriesFLEXX
SEERUp to 20
HSPFUp to 10
RefrigerantR410A
Heating Operation Range-22°F to 75°F
Cooling Operation Range5°F to 122°F
Operating Temperature Range (Heating)-22°F to 75°F
Operating Temperature Range (Cooling)5°F to 122°F
Energy Efficiency Ratio (EER)Up to 12.5
Dimensions (Outdoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model
Compressor TypeInverter
Power Supply208/230V, 1Ph, 60Hz
Noise LevelAs low as 55 dB(A)

Related product manuals