Water Monitoring System
Ver.5.0.1 – Revision August 2022 Page 15 of 111
3 Safety Aspects
Before operating the system, read and understand the entire operating manual.
WARNING/ATTENTION
Follow the instructions.
Please ensure correct connection of all power and signal cables before operating
the water monitoring system.
The PAH sensor module and Turbidity sensor modules use UV and IR light. Please
do not stare into the lenses – it can cause damage to your eyes.
The pH/Temperature sensor uses an electrode which is
stored inside the system in a separate container to
maximize electrode lifetime. The electrode is delivered
with a safety cap on to ensure the electrode is kept moist.
The electrode will be damaged if it dries out. The cap must
be removed prior to start-up of the system. The
pH/temperature sensor is also fitted with a plug to prevent
moisture from entering the electrical connection. The plug
must be removed, and the electrode fitted prior to start-up.
The suction line must not be blocked when the pump is running. The pump will be
damaged if the suction line is blocked.
Do not run pump dry.
Avoid air in the sampling system due to risk of air lock leading to flow alarm and
damage of the pump.
Always ensure a positive suction pressure and keep discharge pressure as low as
possible in order to maximize pump lifetime.
Pay attention to the temperature of the pump. Time to cool down can be needed
prior to attempting restart.
Do not block the drain or outlet from a safety valve. Damage of components will
occur.
Check the function of the safety valve to ensure correct operation. Follow the
planned maintenance program.
The system is only suitable for installation in a safe, non-hazardous area and is not
suitable for use with flammable sample liquids. Non-wetted components such as
cabinet enclosure etc. must be kept dry and clean.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GREEN INSTRUMENTS Maritime G6100 and is the answer not in the manual?

GREEN INSTRUMENTS Maritime G6100 Specifications

General IconGeneral
BrandGREEN INSTRUMENTS
ModelMaritime G6100
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals