Page #10 background image
10
distribution grid company. This connection must be made only by qualified technical personnel to
connect, and only after receiving appropriate approvals, as required by the local authority having
jurisdiction.
2.3 Safety instruction
The MIN TL-X Inverters is designed and tested according to international safety requirements
IEC62109-1,CE,VDE0126-1-1, AS4777; however, certain safety precautions must be observed
when installing and operating this inverter. Read and follow all instructions, cautions and warnings
in this installation manual. If questions arise, please contact Growatts technical services at +86
(0)755 2747 1900.
2.4 Assembly Warnings
WARNING
Prior to installation, inspect the unit to ensure absence of any transport
or handling damage, which could affect insulation integrity or safety
clearances; failure to do so could result in safety hazards.
Assemble the inverter per the instructions in this manual. Use care
when choosing installation location and adhere to specified cooling
requirements.
Unauthorized removal of necessary protections, improper use,
incorrect installation and operation may lead to serious safety and
shock hazards and/or equipment damage.
In order to minimize the potential of a shock hazard due to hazardous
voltages, cover the entire solar array with dark material prior to
connecting the array to any equipment.
CAUTION
Grounding the PV modulesThe MIN TL-X is a transformerless
inverter. That is why it has no galvanic separation. Do not ground the
DC circuits of the PV modules connected to the MIN TL-X. Only
ground the mounting frame of the PV modules.If you connect
grounded PV modules to the MIN TL-X, the error message "PV ISO
Low".
Comply with the local requirements for grounding the PV modules and
the PV generator. GROWATT recommends connecting the generator
frame and other electrically conductive surfaces in a manner which
ensures continuous conduction with ground in order to have optimal
protection of the system and personnel.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt MIN 5000 TL-X and is the answer not in the manual?

Growatt MIN 5000 TL-X Specifications

General IconGeneral
Max. DC Voltage550 V
Nominal AC Output Power5000 W
Max. Efficiency98.4%
MPPT Efficiency99.9 %
Weight10.8 kg
Protection RatingIP65
Number of MPP Trackers2
Max. Input Current per MPPT11 A
Max. AC Power5000 W
Nominal AC Voltage230 V
AC Voltage Range180 V - 280 V
Nominal Grid Frequency50 Hz / 60 Hz
Total Harmonic Distortion<3%
DC SwitchYes
Protection ClassClass I
TopologyTransformerless
CoolingNatural convection
Max. PV Input Power6000 W
Max. PV Input Voltage550 V
Max. Input Current22 A
AC Output Voltage230 V
AC Output Frequency50 Hz / 60 Hz
Peak Efficiency98.4%
Operating Temperature Range-25°C to 60°C
Power Factor Adjustment Range0.8 leading - 0.8 lagging
Dimensions (W x H x D)375 x 350 x 160 mm