5.3.2 Fixed the inverter on the wall
WARNING
Falling equipment can cause serious or even fatal injury, never
mount the inverter on the bracket unless you are sure that the
mounting frame is really firmly mounted on the wall after
carefully checking.
Type1:
Rise up the inverter a little higher than the bracket. Considered the weight
of them.During the process please maintain the balance of the inverter.
Hang the inverter on the bracket through the match hooks on bracket.
After confirming the inverter is fixed reliably, fasten one M6 safety-lock sockets
head cap screws on the right or left side firmly to prevent the inverter from being
lifted off the bracket.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt MIN 5000 TL-X and is the answer not in the manual?

Growatt MIN 5000 TL-X Specifications

General IconGeneral
Max. DC Voltage550 V
Nominal AC Output Power5000 W
Max. Efficiency98.4%
MPPT Efficiency99.9 %
Weight10.8 kg
Protection RatingIP65
Number of MPP Trackers2
Max. Input Current per MPPT11 A
Max. AC Power5000 W
Nominal AC Voltage230 V
AC Voltage Range180 V - 280 V
Nominal Grid Frequency50 Hz / 60 Hz
Total Harmonic Distortion<3%
DC SwitchYes
Protection ClassClass I
TopologyTransformerless
CoolingNatural convection
Max. PV Input Power6000 W
Max. PV Input Voltage550 V
Max. Input Current22 A
AC Output Voltage230 V
AC Output Frequency50 Hz / 60 Hz
Peak Efficiency98.4%
Operating Temperature Range-25°C to 60°C
Power Factor Adjustment Range0.8 leading - 0.8 lagging
Dimensions (W x H x D)375 x 350 x 160 mm