1. In parameter field, select environment:addren, choose ON, then click on
save. After that, Shine WebBox could operate environmental monitor. The address
of the environmental monitor is 36, which should not be modified. Please set the
address of environmental monitor to 36 in its own LCD interface, and select
Modbus” protocol.
2. In parameter field, select Ammeter:addren, choose ON, then click on
save. After that, the communication between smart-meter and Shine WebBox has
been set up.
Environment:addren
Ammeter:addren
36
37
ON
ON
Note:
specified by Growatt, ensuring to communicate well.
the manufactures of environmental monitor and smart-meter have been
4.2.2 Setting Data and Time
In “parameter” field, select “enable_write Enter the data and time Save.
System_time:
2013-01-09 10:36:52
Enable_write
4.2.3 Data Update Frequency
1. In parameterfield, you can choose the data updating frequency from the drop-
down list. The default setting is 2s. For example, set the updating frequency to 1.5s.
Delay timeS):
1.5
2. Click on “save. The configuration is OK.
20