1.Under the Basic Para, you can see the setup options below after pressing Enter for 1S:
In the basic Parameter, you can set language (English, Italian, German), system time,
lead-acid cell charging voltage (default is 58V), discharge low voltage (default is 48V)
and lead-acid constant current (default is 60A).
Chart 6.6
2. Under the Back Up, you can see the setup options below after pressing Enter for 1S:
In the back up you can set EPS, including enable or disable (default is enable), AC
voltage(default is 230V) and frequency (default site 50HZ).
3.Under the Priority, you can see the setup options below after pressing Enter:
Chart 6.8
Note:
1.Power Rate is used to set up power of battery. So different battery may have the
different power, customer need to check the max power of battery.
2.Time setting is 24-hour. If the end time is less than beginning time, it defaults to
spanning days.
3.Under the MODE Change, you can see the setup options below after pressing Enter:
Chart 6.9
The MODE change has two options what are sensor and battery type, sensor is cable CT
(default), meter and SP-CT(wireless RF transfer). In the battery type, you can choose
lithium battery or lead-acid battery.
Chart 6.7
60 HZ
Press “Enter” Key more than 1
second to make sure
Press “Enter” Key more than 1
second to make sure
Work Mode
BackUp
EPS Setup
Press “down” Key
to next item
Work Mode
Backup :Enable
Work Mode
AC Volt:230 V
Work Mode
AC Freq: 50 HZ
Disable
240 V
208 V
Work Mode
Work Mode
Language
Work Mode
English
Italian
German
Work Mode
System time
Work Mode
xxD/xxM /xxxxY
Work Mode
Lead
-
acid CV
Work Mode
58.0 V
Work Mode
Lead
-
acid CC
Work Mode
60 A
Press
“enter”
key more
than 1 seconds to make sure
Press
“down”
key
to the next item
Press key more
than 1 seconds to make sure
Range from 55 to 60V,
and the accuracy is 0.1V
Range from 0 to 83A , and
the accuracy is 0 .1A
Work Mode
Lead
-
acid LV
Work Mode
48V
Range from 42 to 50 V,
and the accuracy is 0.1V
Basic Parameter
Only display when
battery type is lead
-
acid
Only display when
battery type is lead
-
acid
Only display when
battery type is lead
-
acid
“enter”
43
44
MODE Change
WorkMode
Sensor
WorkMode
Cable CT
WorkMode
Meter
SP-CT
Battery Type
WorkMode
Lithium
WorkMode
Lead- acid
Press
key to
make sure
Press
key
to the next item
Press
key
to make sure
“enter”
“down”
“enter”
If battery first is
choosen
Work Mode
Opt:Load First(Default)
Bat First
Grid First
Work Mode
AC CHG:Enable
Disable
Work Mode
Priority
Work Mode
Bat First:OK
Choose “OK”to
next item
Work Mode
SC:_ _ _ _
Work Mode
00:00
-
00:00
Work Mode
Time
Work Mode
Stop SOC :100 %
Work Mode
Power Rate:100 %
Work Mode
Save:OK
NO
If you need to enable AC
charging function,you
need key password
If Grid first is
choosen
Work Mode
Grid First:OK
NO
NO
Press
Key
to next item
Choose
“OK”
to
next item
Work Mode
00:00-00:00
Work Mode
Time
Work Mode
Stop SOC:5%
Work Mode
Power Rate :100 %
Work Mode
Save:OK
NO
Press “down” Key
to next item
Range from 50 %
-
100%,and
acccuracy is 1%
Range from 10 %
-
100 %,and
acccuracy is 10 %
Range from 50% -100% ,and
acccuracy is 1%
Range from 10% -100% ,and
acccuracy is 10%
“down”

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH-UP Series and is the answer not in the manual?

Growatt SPH-UP Series Specifications

General IconGeneral
TypeHybrid Inverter
Protection RatingIP65
Number of MPPTs2
AC Voltage Range180-280V
THDi<3%
AC Grid Frequency50/60Hz
Communication InterfacesWi-Fi, RS485, USB
Nominal AC Voltage230 V
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Cooling