6.3 Country setting
Growatt can provide machines of various specifications. After receiving the machines, customers can set the
corresponding specifications by dialing the LCD according to their national safety regulations.
Basic Parameter
WorkMode
WorkMode
Configuration
WorkMode
MODE Change
WorkMode
Priority
WorkMode
BackUp
Press enter key more than
3 seconds into setup mode
Press down key
to the next item
Press enter key more
than 1 seconds to make sure
Default Set
WorkMode
Auto Test
WorkMode
ExportLimit
WorkMode
Chart 6.1
Caution :
When you setting the DIP, you must turn off PV switch, AC
breaker and Battery to make sure all of the power are off.
Caution:
1. After setting the DIP, please power on the inverter and check
the model display (show as 6.3.1). If the model display is match
what you want, it means your setting is successful.
2. You need to calibrate the time that the machine is showing
after inverter starts up.
If the country is set incorrectly, please shut down the inverter

Other manuals for Growatt SPH5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH5000 and is the answer not in the manual?

Growatt SPH5000 Specifications

General IconGeneral
ModelSPH5000
TypeHybrid Inverter
Rated Power5000 W
Max. DC Voltage550 V
Max. Output Current22 A
Weight25 kg
Max. DC Power6000 W
Start Voltage150 V
Nominal DC Voltage360 V
Number of MPP Trackers2
AC Nominal Power5000 W
Max. AC Apparent Power5000 VA
AC Nominal Voltage230 V
AC Voltage Range180-280V
Nominal Grid Frequency50/60Hz
Total Harmonic Distortion (THDi)<3%
Power Factor Adjustment Range0.8 leading to 0.8 lagging
DC Injection Current<0.5% In
Switching Time<10 ms
Max. Charge/Discharge Power5000 W
Max. Charge/Discharge Current100 A
Protection degreeIP65
Max. PV Input Voltage550 V
Cooling MethodNatural Convection
Communication with BMSCAN
Operating Temperature Range-25°C to 60°C
MPPT Voltage Range120 V - 550 V