15
7.1 Factory setting
The pump is factory-set to AUTOADAPT without auto-
matic night-time duty.
7.2 Control panel
The control panel, fig. 11, incorporates:
For further information, see section 8. Fault finding
chart.
Fig. 11 Control panel
7.2.1 Control mode setting
Description of function, see section 6.1 Control
modes.
To change the control mode, press , pos. 3,
according to this cycle:
Fig. 12 Cycle of control modes
Automatic night-time duty can be activated together
with each of the control modes.
The light symbols in pos. 4, see fig. 11, indicate the
pump settings:
"–" = no light.
7.2.2 Setpoint setting
Set the setpoint of the pump by pressing or
when the pump has been set to proportional-pres-
sure control, constant-pressure control or constant-
curve duty.
The light fields, pos. 5, on the control panel indicate
the setpoint set.
At high liquid temperatures, the pump may
be so hot that only the buttons should be
touched to avoid burns.
Pos. Description
1 Buttons for setting
2
• Indicator lights for operating and fault
indication and
• symbol for indication of external control
3 Button for change of control mode
4
Light symbols for indication of control
mode and night-time duty
5
Light fields for indication of head, flow and
operating mode
TM03 0379 5004
AUTO
EXT
m
3
/h
100%
MAX
STOP
5
4
1
2
3
ADAPT
TM03 1288 1505
Light in Control mode
Automatic
night-time
duty
AUTO
ADAPT AUTOADAPT NO
Constant pressure NO
Proportional
pressure
NO
– Constant curve NO
AUTO-
ADAPT
AUTOADAPT YES
Constant pressure YES
Proportional
pressure
YES
– Constant curve YES
AUTO
ADAPT
AUTO
ADAPT
+
+
+