16
MAGNA 25-100, 32-100, 40-100(D), 50-100:
The light fields can indicate a maximum setpoint of
9metres.
The "MAX" light field indicates that the pump is oper-
ating like an uncontrolled pump on the max. curve up
to 10 metres.
Fig. 13 Light fields xx-100
MAGNA 25-60, 32-60:
The light fields can indicate a maximum setpoint of
5metres.
The "MAX" light field indicates that the pump is oper-
ating like an uncontrolled pump on the max. curve up
to 6 metres.
Fig. 14 Light fields xx-60
7.2.3 Setting to max. curve duty
Description of function, see section 6.5 Max. or min.
curve duty.
To change over to the max. curve, press continu-
ously until "MAX" illuminates, see fig. 15. To change
back, press continuously until the desired setpoint
is indicated.
Fig. 15 Max. curve
7.2.4 Setting to min. curve duty
Description of function, see section 6.5 Max. or min.
curve duty.
To change over to the min. curve, press continu-
ously until "MIN" illuminates, see fig. 16. To change
back, press continuously until the desired setpoint
is indicated.
Fig. 16 Min. curve
7.2.5 Start/stop of pump
To stop the pump, press continuously until
"STOP" illuminates. When the pump is stopped, the
green indicator light will be flashing.
To start the pump, press continuously.
Note: If the pump is to be stopped, it is re-
commended to use the start/stop input, the R100 or
to switch off the electricity supply. In this way, the
setpoint will remain unchanged when the pump is
started again.
7.2.6 Resetting of fault indications
The fault indications are reset by briefly pressing any
button. The settings remain unchanged. If the fault
has not disappeared, the fault indication will re-
appear. The time until the fault reappears may vary
from 0 to 255 seconds.
7.3 R100 remote control
The pump is designed for wireless communication
with the Grundfos R100 remote control. The R100
communicates with the pump via infra-red light.
During communication, the R100 must be pointed at
the pump control panel. When the R100 is communi-
cating with the pump, the red indicator light will flash
rapidly.
The R100 offers additional possibilities of setting and
status displays for the pump.
TM03 0380 5004TM02 0483 4800TM03 0381 5004
MAX
H
Q
TM03 0382 5004
m MIN
H
Q